NC-1000 Ethernet RJ45 TCP/IP Network Remote Control Board with 8 Channel Relays Integrated 250V AC 485 Network Controller

NC-1000 Ethernet RJ45 TCP/IP Network Remote Control Board with 8 Channel Relays Integrated 250V AC 485 Network Controller

$36.36 $32.99

Type: Case Only

Case Only
Board Only
Board+Case

Description:1. Ethernet TCP/IP RJ45 Port.2. Onbaord WEB server allows accessing and controlling the relay via WEB.3. 8-Channel 250V/AC 10A Relay control individually.4. Thicker tinning for relay's wiring.5. 8 external control...

🟢 In Stock

✔️ WORLDWIDE SHIPPING
✔️ 30 DAYS RETURN GUARANTEE
✔️ SECURE CHECKOUT

visamasteramerican expressgoogle paypaypal
Tags: shop
Description
Description:

1. Ethernet TCP/IP RJ45 Port.
2. Onbaord WEB server allows accessing and controlling the relay via WEB.
3. 8-Channel 250V/AC 10A Relay control individually.
4. Thicker tinning for relay's wiring.
5. 8 external control outputs and active low level can control switch or sensor, etc.
6. Wide operating voltage range: 7-24V DC power supply.
7. Provide protocol for reengineering: When connected to router, it allows access control via for Android, Tablet, Windows system from anywhere in the world with network.
8. Supports status return, can display current status of the relays.
9. IP Port can be modified.
10. With Reset function, short press to reset, long press to restore factory setting.
11. Supports 485 networking.
12. Internal circuit protection: with optocoupler to prevent from external voltage surge.

Features:

1: trigger signal input
IN1-IN8 has two ways to be inputted: A: Non-contact signal, release after IN ground; B: latch signal, IN ground can control the corresponding relay switch.
2: serial port communication protocol 
1 way open: FD 02 20 01 01 5D
1 way close: FD 02 20 01 00 5D
2 way open: FD 02 20 02 01 5D
2-way close: FD 02 20 02 00 5D
3-way open: FD 02 20 03 01 5D
3-way close: FD 02 20 03 00 5D
4-way open: FD 02 20 04 01 5D
4-way close: FD 02 20 04 00 5D
5 way open: FD 02 20 05 01 5D
5-way close: FD 02 20 05 00 5D
6 way open: FD 02 20 06 01 5D
6-way close: FD 02 20 06 00 5D
7 way open: FD 02 20 07 01 5D
7 way close: FD 02 20 07 00 5D
8 way open: FD 02 20 08 01 5D
8 way close: FD 02 20 08 00 5D
Open 1-8: FD 02 20 F8 88 5D
1-8 pass: FD 02 20 F8 80 5D
Back: FB 21 55 xx XX FF: xx XX eac byte means 1ch high byte corresponding to the 16ch, low byte corresponding to 1ch
3: Network controller port
IP: 192.168.1.4
Port number: 30000
Enter http://192.168.1.4/30000 in the browser's address bar, and then you will be able to control the corresponding switch.
4. Long press 'RESET' till the light is out. Then it will restore the factory default IP and port number.

Package Included:

1 x 8 Channels Relay Integrated Remote Controller Board
1 x Case