8 Channel Solid State High Power 3-5VDC 5A Relay Module
Description: SSR-GJ series for small high-power solid-state relays, input control voltage is 3~5VDC, output adopts a unidirectional thyristor reverse parallel, dv/dt resistant ability is high, the output load voltage range of...
🟢 In Stock
✔️ WORLDWIDE SHIPPING
✔️ 30 DAYS RETURN GUARANTEE
✔️ SECURE CHECKOUT
Description
Description:
SSR-GJ series for small high-power solid-state relays, input control voltage is 3~5VDC, output adopts a unidirectional thyristor reverse parallel, dv/dt resistant ability is high, the output load voltage range of 5~220VDC. Great to meet customers various requirements in different places.
Specification:
The photoelectric isolation
The 4000V dielectric withstanding voltage
The 0 or random conducting switch
The PCB type installationThe SCR output
Have extremely high surge current capability
Built in RC absorption circuit
It can provide LED indicate the working state of products
Environmental friendly ( in line with the ROHS requirements )
Input ( control ) parameters ( TA=25Ôäâ)
Input voltage range: 3~5VDC
Ensure that the turn-on voltage: 3VDC
Ensure that the turn-off voltage: 1VDC
Input current ( typical): 18Ma
Input current ( max): 25mA
Reverse polarity voltage ( DC ):-5VDC
Output ( load ) parameters ( TA=2Ôäâ)
Output voltage range: 5~220VDC
Maximum transient voltage: 800Vpk
Maximum output current : 1Ma’
Maximum output voltage: 1.5Vrms;
Maximum load current: 5A
Maximum surge current (10ms ): Rated current of 20 times
The minimum power factor: 0.5
Minimum working current: 50MA
High level action
Low level cut-off
Control panel input: 3~5VDC
Power supply input: 3~5VDC
Package includes:
1 x Relay module
SSR-GJ series for small high-power solid-state relays, input control voltage is 3~5VDC, output adopts a unidirectional thyristor reverse parallel, dv/dt resistant ability is high, the output load voltage range of 5~220VDC. Great to meet customers various requirements in different places.
Specification:
The photoelectric isolation
The 4000V dielectric withstanding voltage
The 0 or random conducting switch
The PCB type installationThe SCR output
Have extremely high surge current capability
Built in RC absorption circuit
It can provide LED indicate the working state of products
Environmental friendly ( in line with the ROHS requirements )
Input ( control ) parameters ( TA=25Ôäâ)
Input voltage range: 3~5VDC
Ensure that the turn-on voltage: 3VDC
Ensure that the turn-off voltage: 1VDC
Input current ( typical): 18Ma
Input current ( max): 25mA
Reverse polarity voltage ( DC ):-5VDC
Output ( load ) parameters ( TA=2Ôäâ)
Output voltage range: 5~220VDC
Maximum transient voltage: 800Vpk
Maximum output current : 1Ma’
Maximum output voltage: 1.5Vrms;
Maximum load current: 5A
Maximum surge current (10ms ): Rated current of 20 times
The minimum power factor: 0.5
Minimum working current: 50MA
High level action
Low level cut-off
Control panel input: 3~5VDC
Power supply input: 3~5VDC
Package includes: